Boiler Control Devices
Physical Properties | |
Type of Device | Boiler Control Devices |
Device Size | 70 mm X 145 mm X 125 mm |
Weight of Device | 316 gram |
Storage Temperature / Operating Temperature | -20 C to +60 C |
Storage Humidity / Operating Humidity | 90% max. (None condensing) |
Installation | Fixed installation |
Operating Conditions | Continuous |
Environmental Ratings | Standard, indoor at an altitude of less than 2000 meters with none condensing humidity. |
Device Supply Voltage and Power | 220V AC |
Temperature Sensor Inputs | NTC(10K) |
Accuracy | +-%1 |
Sensor Break Protection | Upscale |
Reading Frequency | 600 ms |
Input Resistance | 1k |
Electrical Life | 50.000 Operation - Full Load |
Display | Display |
Compliant Standards | CE, TSE |
Operational Properties | |
Room thermostat can work dependent. In this way, it works depending on the temperature of the room and provides energy saving as well as providing a comfortable warming pleasure by fixing the room temperature. | |
Detects that the fuel has run out and automatically stops the operation of the boiler. In this way, the boiler does not work in vain. | |
Automatic Frost Protection feature prevents the installation water from freezing in cold weather when the boiler is off. | |
Thermostat settings can be made with extremely high sensitivity. | |
When the temperature reaches 35 degrees, the circulation pump switches on automatically and automatically turns off when it falls below 30 degrees. | |
It reads temperature with 1degree accuracy and processes with 1degree precision. | |
Fuel Fan (bellows fan) and circulation pump can be operated directly without the use of contactors. | |
All motor and electrical connections can be made with plug-in terminal blocks. | |
Both mounting and electrical connections are demounted. In this way, manufacturing and service labor is minimized. |